Menu
Your Cart
C008 replaceable membrane 3H electrolytic cell
C008 replaceable membrane 3H electrolytic cell
C008 replaceable membrane 3H electrolytic cell
C008 replaceable membrane 3H electrolytic cell

C008 replaceable membrane 3H electrolytic cell

1. The electrolytic cell is upgraded on the basis of C008


2. The electrolytic cell realizes atmosphere protection by adding valves and aeration devices, and the valve connected to the aeration device is the direction of air intake


3. The electrolytic cell is an absolutely sealed system and can be evacuated through a valve (less than -1 Mpa). The electrolytic cell can be slightly pressurized, and the pressure cannot be greater than 0.5 MPa for safety reasons.


Due to process limitations, the inner glass of the double-layer electrolytic cell is relatively weak, so pressurization is prohibited. 4. The working electrode, auxiliary electrode, and reference electrode of the electrolytic cell must be customized to match the electrolytic cell.


5. The reference electrode and the working electrode of the electrolytic cell are divided into compartments, and the Lukin capillary is connected to effectively reduce the R drop.


6. The aperture of the tip part of the electrolytic cell Lukin capillary projecting into the working electrode chamber cannot be greater than 0.2mm,


7. Agar can be added to the Lukin capillary of the electrolytic cell to reduce the flow rate of the electrolyte.


8. The reference electrode chamber of the electrolytic cell is sealed with internal threads, which must be sealed when in use to effectively prevent the reference electrode chamber and the working electrode chamber from leaking due to the communicating device effect.


9. The cell body material of the electrolytic cell is high borosilicate glass


10. This electrolytic cell is often used in a three-electrode system. The volume of the electrolytic cell ranges from 10ml to 500ml, and it can also be customized according to requirements.


11. The electrolytic cell is an absolutely sealed electrolytic cell system. The cathode chamber (working electrode) and the anode chamber (contrast electrode) are separated by ionic membrane (provided by the user), and the two chambers are sealed and linked by a chain, which facilitates the replacement of the diaphragm.


12. The glass sealing part of the working electrode chamber and the contrast electrode chamber of the electrolytic cell is designed with an external threaded port, and the inner core adopts a 360-degree rotating PTFE, so that the electrode accurately corresponds to the channel (the general electrode is parallel to the membrane). Tightly seal the outer cover made of POM material.


13. The electrolytic cell is equipped with an aeration device that can ventilate below the liquid surface. Aeration devices of different shapes are selected for the atmosphere according to different experiments. For example, straight aeration is used for carbon reduction, and L-type aeration is used for nitrogen reduction.


14. The electrolytic cell can add a sampling port on the cell body, and an additional cost is required at this time. 15. The 10ml electrolytic cell is designed with internal thread, and its shape is basically the same as that of C008-10 series. For details, please refer to "C008-10". However, no valve can be added.


16. The electrolytic cell is divided into single-layer and double-layer forms


17. The double layer adds the function of a constant temperature water bath on the basis of the single layer. The constant temperature water is continuously passed into the jacket layer of the electrolytic cell to make the solution under test in the electrolytic cell reach a constant temperature effect.

Product Inquiry